Follow

Wave Plus - Sensor Specifications

 

AIR QUALITY - SENSOR SPECIFICATIONS

Sensor sampling interval: 5 minute

Sensor Resolution:

Temperature ± 0.1°F (0.1° C)

Humidity ± 1%

Pressure ± 0.15hPa

Settling time:

TVOC ~ 7 days

CO2 ~ 7 days

CO2 details:

NDIR Sensor (Non-Dispersive Infra-Red)

Measurement range 400–5000 ppm

Non condensing 0 – 85%RH

Optimum Accuracy ±30ppm ±3% within 15 – 35°C (60 - 95°F) and 0 – 80%RH can be reached after multiple settling cycles on locations with natural indoor CO2 fluctuations

 

RADON SENSOR SPECIFICATIONS

Radon sampling: Passive diffusion chamber

Detection method: Alpha spectrometry

Measurement range: 0 – 500 pCi/L

Accuracy/precision:

After 7 days:  σ ~ 10 % at 5 pCi/L

After 2 months: σ ~ 5 % at 5 pCi/L

 